PA oblique foot X-ray positioning

One of the routine foot views. The patient lies face down, the beam passes back to front (PA), straight on to the receptor, and the centring point is the base of the third metatarsal.

By the ScanFlo Editorial Team · Updated

In this section · X-ray positioning

X-ray positioning/Foot

Still being checked: a radiographer is reviewing this guide. If your department does it differently, follow your department.

Patient position

Prone. Prone, the foot turned on the detector as shown so the lateral metatarsals separate.

Centring & collimation

Central ray

PA

Centre: the base of the third metatarsal.

Beam: PA, perpendicular to the receptor.

Collimate: toes to the calcaneus

Distance, receptor & grid

SettingValueNotes
SID100 cm
Receptor18 × 24 cmportrait
PlacementTabletopNo grid
AngulationNonePerpendicular to the receptor

Marker & breathing

  • Marker: R or L marker on the side nearest the detector
  • Breathing: No breathing instruction needed.

Exposure by patient size

Treat these as a starting point. Your detector, your generator and the patient in front of you will all move the numbers.

Patient sizekVmAs (chart)mAs (DR default)
XS460.80.5
S461.250.5
M461.60.63
L462.51

These start from a classic film-screen chart (46 kV, 25 mAs at 140 cm) and are adjusted for a digital detector at 100 cm. The DR column is what ScanFlo's console suggests; each step up or down changes the mAs by about a quarter.

Image quality checklist

  • The lateral metatarsals and cuboid are separated.
  • The anatomical side marker is visible, correct and clear of the anatomy.
  • Collimation borders are visible on all sides, no wider than the area requested.

Faults & how to fix them

FaultCauseFix
Metatarsals overlapToo little rotationRotate further.

Common questions

Where do you centre for a foot PA oblique X-ray?
The centring point is the base of the third metatarsal.
What distance and beam angle does a foot PA oblique need?
100 cm from the tube to the receptor. The beam passes back to front (PA), straight on to the receptor.
What size receptor, and do you need a grid?
Use an 18 × 24 cm receptor, portrait, on the tabletop. No grid is needed.
Where does the lead marker go?
R or L marker on the side nearest the detector.
What goes wrong most often on a foot PA oblique?
Metatarsals overlap. Usual cause: too little rotation. The fix: rotate further.

Try it in ScanFlo: the ScanFlo XR X-ray Room, coming soon, lets you set up a foot pa oblique in a 3D room and score your positioning. See ScanFlo XR →

Written by the ScanFlo team from everyday radiographic practice.