ScanFlo

Lateral foot X-ray positioning

An extra foot view, used when a routine one is not enough. The patient lies on their side, the beam passes from side to side, straight on to the receptor, and the centring point is the base of the metatarsals.

By the ScanFlo Editorial Team · Updated

In this section · X-ray positioning

X-ray positioning/Foot

Still being checked: a radiographer is reviewing this guide. If your department does it differently, follow your department.

Patient position

Lateral recumbent. Lying on the side examined, knees bent; the lateral border of the foot on the detector.

Centring & collimation

Central ray

lateral

Centre: the base of the metatarsals.

Beam: lateral, perpendicular to the receptor.

Collimate: toes to the calcaneus and ankle joint

Distance, receptor & grid

SettingValueNotes
SID100 cm
Receptor24 × 30 cmlandscape
PlacementTabletopNo grid
AngulationNonePerpendicular to the receptor

Marker & breathing

  • Marker: R or L marker on the side nearest the detector
  • Breathing: No breathing instruction needed.

Exposure by patient size

Treat these as a starting point. Your detector, your generator and the patient in front of you will all move the numbers.

Patient sizekVmAs (chart)mAs (DR default)
XS460.80.5
S461.250.5
M461.60.63
L462.51

These start from a classic film-screen chart (46 kV, 25 mAs at 140 cm) and are adjusted for a digital detector at 100 cm. The DR column is what ScanFlo's console suggests; each step up or down changes the mAs by about a quarter.

Image quality checklist

  • Metatarsals superimposed; ankle joint included.
  • The anatomical side marker is visible, correct and clear of the anatomy.
  • Collimation borders are visible on all sides, no wider than the area requested.

Faults & how to fix them

FaultCauseFix
RotationFoot tiltedMake the sole perpendicular.

Common questions

Where do you centre for a foot lateral X-ray?
The centring point is the base of the metatarsals.
What distance and beam angle does a foot lateral need?
100 cm from the tube to the receptor. The beam passes from side to side, straight on to the receptor.
What size receptor, and do you need a grid?
Use a 24 × 30 cm receptor, landscape, on the tabletop. No grid is needed.
Where does the lead marker go?
R or L marker on the side nearest the detector.
What goes wrong most often on a foot lateral?
Rotation. Usual cause: foot tilted. The fix: make the sole perpendicular.

Try it in ScanFlo: the ScanFlo XR X-ray Room, coming soon, lets you set up a foot lateral in a 3D room and score your positioning. See ScanFlo XR →

Written by the ScanFlo team from everyday radiographic practice.

← All foot projections

Start freeBook a demo