AP oblique foot X-ray positioning

An extra foot view, used when a routine one is not enough. The patient sits, the beam passes front to back (AP), tilted 15° towards the head, and the centring point is the base of the third metatarsal.

By the ScanFlo Editorial Team · Updated

In this section · X-ray positioning

X-ray positioning/Foot

Still being checked: a radiographer is reviewing this guide. If your department does it differently, follow your department.

Patient position

Sitting. Sitting on the table, the foot angled on the detector.

Centring & collimation

Central ray

AP

Centre: the base of the third metatarsal.

Beam: AP, angled 15° toward-head.

Collimate: the whole foot

Distance, receptor & grid

SettingValueNotes
SID100 cm
Receptor18 × 24 cmportrait
PlacementTabletopNo grid
Angulation15°toward-head

Marker & breathing

  • Marker: R or L marker on the side nearest the detector
  • Breathing: No breathing instruction needed.

Exposure by patient size

Treat these as a starting point. Your detector, your generator and the patient in front of you will all move the numbers.

Patient sizekVmAs (chart)mAs (DR default)
XS460.80.5
S461.250.5
M461.60.63
L462.51

These start from a classic film-screen chart (46 kV, 25 mAs at 140 cm) and are adjusted for a digital detector at 100 cm. The DR column is what ScanFlo's console suggests; each step up or down changes the mAs by about a quarter.

Image quality checklist

  • Tarsal bones shown with less overlap.
  • The anatomical side marker is visible, correct and clear of the anatomy.
  • Collimation borders are visible on all sides, no wider than the area requested.

Faults & how to fix them

FaultCauseFix
OverlapFoot flatAngle the foot.

Common questions

Where do you centre for a foot AP oblique X-ray?
The centring point is the base of the third metatarsal.
What distance and beam angle does a foot AP oblique need?
100 cm from the tube to the receptor. The beam passes front to back (AP), tilted 15° towards the head.
What size receptor, and do you need a grid?
Use an 18 × 24 cm receptor, portrait, on the tabletop. No grid is needed.
Where does the lead marker go?
R or L marker on the side nearest the detector.
What goes wrong most often on a foot AP oblique?
Overlap. Usual cause: foot flat. The fix: angle the foot.

Try it in ScanFlo: the ScanFlo XR X-ray Room, coming soon, lets you set up a foot ap oblique in a 3D room and score your positioning. See ScanFlo XR →

Written by the ScanFlo team from everyday radiographic practice.