Oblique pelvis X-ray positioning

An extra pelvis view, used when a routine one is not enough. The patient lies on their back, turned at an angle, the beam passes front to back (AP), straight on to the receptor, and the centring point is the hip of interest.

By the ScanFlo Editorial Team · Updated

In this section · X-ray positioning

X-ray positioning/Pelvis

Still being checked: a radiographer is reviewing this guide. If your department does it differently, follow your department.

Patient position

Oblique, supine. Supine, raise the side away from the area of interest 45°.

Centring & collimation

Central ray

AP

Centre: the hip of interest.

Beam: AP, perpendicular to the receptor.

Collimate: the hemipelvis and acetabulum

Distance, receptor & grid

SettingValueNotes
SID100 cm
Receptor35 × 43 cmlandscape
PlacementTable buckyGrid in
AngulationNonePerpendicular to the receptor

Marker & breathing

  • Marker: R or L marker on the side nearest the detector
  • Breathing: Suspend respiration.

Exposure by patient size

Treat these as a starting point. Your detector, your generator and the patient in front of you will all move the numbers.

Patient sizekVmAs (chart)mAs (DR default)
XS7012.55
S70208
M702510
L704016

These start from a classic film-screen chart (70 kV, 50 mAs at 140 cm) and are adjusted for a digital detector at 100 cm. The DR column is what ScanFlo's console suggests; each step up or down changes the mAs by about a quarter.

Image quality checklist

  • Acetabular columns shown.
  • The anatomical side marker is visible, correct and clear of the anatomy.
  • Collimation borders are visible on all sides, no wider than the area requested.

Faults & how to fix them

FaultCauseFix
Wrong column shownRotated the wrong wayCheck which side is raised.

Common questions

Where do you centre for a pelvis oblique X-ray?
The centring point is the hip of interest.
What distance and beam angle does a pelvis oblique need?
100 cm from the tube to the receptor. The beam passes front to back (AP), straight on to the receptor.
What size receptor, and do you need a grid?
Use a 35 × 43 cm receptor, landscape, in the table bucky. A grid is needed.
What should the patient do with their breathing?
Ask them to stop breathing for the moment of the exposure.
What goes wrong most often on a pelvis oblique?
Wrong column shown. Usual cause: rotated the wrong way. The fix: check which side is raised.

Try it in ScanFlo: the ScanFlo XR X-ray Room, coming soon, lets you set up a pelvis oblique in a 3D room and score your positioning. See ScanFlo XR →