AP knee X-ray positioning

One of the routine knee views. The patient lies on their back, the beam passes front to back (AP), straight on to the receptor, and the centring point is 1 cm below the apex of the patella.

By the ScanFlo Editorial Team · Updated

In this section · X-ray positioning

X-ray positioning/Knee

Still being checked: a radiographer is reviewing this guide. If your department does it differently, follow your department.

Patient position

Supine. Supine, the detector on the table under the knee, the foot rotated slightly in and steadied with a sandbag.

Centring & collimation

Central ray

AP

Centre: 1 cm below the apex of the patella.

Beam: AP, perpendicular to the receptor.

Collimate: the joint with a quarter of femur and tibia

Distance, receptor & grid

SettingValueNotes
SID100 cm
Receptor18 × 24 cmportrait
PlacementTabletopNo grid
AngulationNonePerpendicular to the receptor

Marker & breathing

  • Marker: R or L marker on the side nearest the detector
  • Breathing: No breathing instruction needed.

Exposure by patient size

Treat these as a starting point. Your detector, your generator and the patient in front of you will all move the numbers.

Patient sizekVmAs (chart)mAs (DR default)
XS531.60.8
S532.51.25
M533.21.6
L5352.5

These start from a classic film-screen chart (53 kV, 40 mAs at 140 cm) and are adjusted for a digital detector at 100 cm. The DR column is what ScanFlo's console suggests; each step up or down changes the mAs by about a quarter.

Image quality checklist

  • The joint space is open.
  • The patella is central over the femur.
  • The anatomical side marker is visible, correct and clear of the anatomy.
  • Collimation borders are visible on all sides, no wider than the area requested.

Faults & how to fix them

FaultCauseFix
Patella off-centreLeg rotatedRotate the foot in slightly.

Common questions

Where do you centre for a knee AP X-ray?
The centring point is 1 cm below the apex of the patella.
What distance and beam angle does a knee AP need?
100 cm from the tube to the receptor. The beam passes front to back (AP), straight on to the receptor.
What size receptor, and do you need a grid?
Use an 18 × 24 cm receptor, portrait, on the tabletop. No grid is needed.
Where does the lead marker go?
R or L marker on the side nearest the detector.
What goes wrong most often on a knee AP?
Patella off-centre. Usual cause: leg rotated. The fix: rotate the foot in slightly.