Lateral tibia and fibula X-ray positioning (lower leg)

One of the routine tibia & fibula views. The patient lies on their side, the beam passes from side to side, straight on to the receptor, and the centring point is the mid-shaft.

By the ScanFlo Editorial Team · Updated

In this section · X-ray positioning

X-ray positioning/Tibia & fibula

Still being checked: a radiographer is reviewing this guide. If your department does it differently, follow your department.

Patient position

Lateral recumbent. On the side examined with the knee slightly bent; the other knee bent further and resting on the table.

Centring & collimation

Central ray

lateral

Centre: the mid-shaft.

Beam: lateral, perpendicular to the receptor.

Collimate: knee to ankle

Distance, receptor & grid

SettingValueNotes
SID100 cm
Receptor18 × 43 cmportrait
PlacementTabletopNo grid
AngulationNonePerpendicular to the receptor

Marker & breathing

  • Marker: R or L marker on the side nearest the detector
  • Breathing: No breathing instruction needed.

Exposure by patient size

Treat these as a starting point. Your detector, your generator and the patient in front of you will all move the numbers.

Patient sizekVmAs (chart)mAs (DR default)
XS531.250.5
S5320.63
M532.50.8
L5341.25

These start from a classic film-screen chart (53 kV, 32 mAs at 140 cm) and are adjusted for a digital detector at 100 cm. The DR column is what ScanFlo's console suggests; each step up or down changes the mAs by about a quarter.

Image quality checklist

  • A true lateral of the shaft with one joint at least.
  • The anatomical side marker is visible, correct and clear of the anatomy.
  • Collimation borders are visible on all sides, no wider than the area requested.

Faults & how to fix them

FaultCauseFix
RotationFoot rolledSteady the foot.

Common questions

Where do you centre for a lower leg lateral X-ray?
The centring point is the mid-shaft.
What distance and beam angle does a lower leg lateral need?
100 cm from the tube to the receptor. The beam passes from side to side, straight on to the receptor.
What size receptor, and do you need a grid?
Use an 18 × 43 cm receptor, portrait, on the tabletop. No grid is needed.
Where does the lead marker go?
R or L marker on the side nearest the detector.
What goes wrong most often on a lower leg lateral?
Rotation. Usual cause: foot rolled. The fix: steady the foot.

Try it in ScanFlo: the ScanFlo XR X-ray Room, coming soon, lets you set up a lower leg lateral in a 3D room and score your positioning. See ScanFlo XR →

Written by the ScanFlo team from everyday radiographic practice.