One of the routine hip views. The patient lies on their back, the beam passes front to back (AP), straight on to the receptor, and the centring point is the femoral neck, 2.5 cm below the mid-inguinal point.

By the ScanFlo Editorial Team · Updated

In this section · X-ray positioning

X-ray positioning/Hip

Still being checked: a radiographer is reviewing this guide. If your department does it differently, follow your department.

Patient position

Supine. Supine; if not injured, turn the foot in 15°. If injured, do not move the leg.

Centring & collimation

Central ray

AP

Centre: the femoral neck, 2.5 cm below the mid-inguinal point.

Beam: AP, perpendicular to the receptor.

Collimate: the hip joint and upper third of the femur

Distance, receptor & grid

SettingValueNotes
SID100 cm
Receptor24 × 30 cmportrait
PlacementTable buckyGrid in
AngulationNonePerpendicular to the receptor

Marker & breathing

  • Marker: R or L marker on the side nearest the detector
  • Breathing: Suspend respiration.

Exposure by patient size

Treat these as a starting point. Your detector, your generator and the patient in front of you will all move the numbers.

Patient sizekVmAs (chart)mAs (DR default)
XS70162
S70253.2
M70324
L70506.3

These start from a classic film-screen chart (70 kV, 63 mAs at 140 cm) and are adjusted for a digital detector at 100 cm. The DR column is what ScanFlo's console suggests; each step up or down changes the mAs by about a quarter.

Image quality checklist

  • The femoral neck is shown in full length.
  • The lesser trochanter is barely visible.
  • The anatomical side marker is visible, correct and clear of the anatomy.
  • Collimation borders are visible on all sides, no wider than the area requested.

Faults & how to fix them

FaultCauseFix
Neck foreshortenedFoot not rotated inRotate in 15° unless injured.

Common questions

Where do you centre for a hip AP X-ray?
The centring point is the femoral neck, 2.5 cm below the mid-inguinal point.
What distance and beam angle does a hip AP need?
100 cm from the tube to the receptor. The beam passes front to back (AP), straight on to the receptor.
What size receptor, and do you need a grid?
Use a 24 × 30 cm receptor, portrait, in the table bucky. A grid is needed.
What should the patient do with their breathing?
Ask them to stop breathing for the moment of the exposure.
What goes wrong most often on a hip AP?
Neck foreshortened. Usual cause: foot not rotated in. The fix: rotate in 15° unless injured.